sysWORXX CANopen IO-X5
Compact & cost effective PT100 / PT1000 CANopen I / O module Extensive diagnostic functions ensure reliable and safe operation

The CANopen IO-X5 is a very compact and cost effective CANopen IO module featuring a high-density of industrial proven IO's.
The module includes a CPU-core with the pre-programmed firmware for CANopen communication and peripherals for the industrial inputs and outputs. Extensive diagnostic routines are implemented to ensure a most reliable and safe operation.
All inputs and outputs as well as configuration parameters are accessible via the CANopen protocol.
The CANopen IO-X5 is a CANopen slave device according CANopen device profile CiA 404 V1.2 and CANopen communication profile CiA 301 V4.02.
Two LED indicate the device state according to CiA 303-3 V1.0.
Module Features
Physical |
|
Size (LxWxH)
|
95x70x58mm
|
Operating Temperature |
-20 to +70°C |
Storage Temperature
|
-20 to +90°C
|
Humidity |
10 to 95% non-condensing (VDE 0110) |
Weight |
ca. 130g |
Installation Method
|
DIN-rail mounting
|
Enclosure Protection Class |
IP20 |
Power Supply
|
|
Operating Voltage
|
24V ± 20%
|
Current Consumption |
< 70mA |
I/O Interfaces |
|
Analog Inputs
|
8 analog input suitable for resistor temperature devices (RTD) (e.g. PT100 or PT1000) in 2- or 3-wire connection scheme
|
Anzeigen |
|
Status LEDs |
Power |
|
Error |
|
CANopen Status |
|
I/O Status |
|
and others |
Particularities |
|
CAN/CANopen
|
CANopen device according to CiA 404 V1.2
|
|
Galvanic isolated CAN-bus interface
|
|
CAN bus termination (120 Ohm resistor) via Jumper
|
Others
|
Non-volatile storage of configuration data
|
|
Watchdog
|
CANopen Features
- Communication profile according to CiA 301 V4.02
- Device profile according to CiA 404 V1.2
- State indicators according to CiA 303-3 V1.0
- Layer Setting Service (LSS) according to CiA 305 V1.1
- 4 TPDO
- Dynamic PDO-Linking and Mapping
- SDO-Server
- Life guarding, Node guarding, Heartbeat Producer
- Emergency Producer
- Minimum Boot-up capability (Slave)
- Minimum NMT boot-up master (Manufacturer extension)
Communication and device configuration:
- Galvanic decoupled CAN-bus driver supports up to 110 CAN-nodes on one bus
- Jumper for CAN-bus termination 120 Ohm
- Hex-encoding switches for setting node-ID and baud rate
- CAN-bus baud rate: 10kBit/s to 1Mbit/s
- High-quality connectors: (included in scope of delivery)
- Power-Supply: 2-pin plug connector
- CAN-bus: 5-pin plug connector
- I/O: single 24-pin plug connector, lockable
- Non-volatile memory for storage of configuration data
- Internal monitoring and diagnostics of: onboard temperature, power supply, memory and other controller internals
- Emergency Messages sent out in case of failure
|